Images obtained from www.purafil.com

Purafil produces and analyzes metal “coupons” that are used to assess how corrosive a given environment is. Industries that include metal components and electronics, or other sensitive materials, need to ensure a mild environment for the stability of their products. Thus, corrosion classification coupons are used in spaces like data centers, server rooms, and museums.

The Purafil corrosion classification coupons are composed of two metal strips: one copper and one silver. The integrity of the metals is confirmed prior to their exposure to air in the intended location. The metal coupons are then exposed to air for 30 days. During this time, corrosive gases, including gases like hydrogen sulfide and sulfur dioxide, will react with copper and silver to form copper and silver sulfides and oxides. These oxides and sulfides form on the surface layers of the metal, increasing the coupon volume. Purafil is able to distinguish between oxide and sulfide formation through x-ray diffraction analysis at their laboratories, but the corrosivity of the environment is categorized based on the height of the accumulated corrosion (e.g. copper oxide + sulfide), measured in a unit of length, Angstroms.

Questions

Title Author Updated Likes Comments
Nothing yet on the topic "corrosion-coupons" -- be the first to post something!


Corrosion classifications

Corrosion classes have been standardized by the International Society for Automation (ISA). The table below, copied from Purafil’s Corrosion Classification Coupon brochure, lists ISA Standard 71.04-2013. Even though copper has a smaller ionic radius than silver, copper is slightly more reactive than silver, so there is a higher copper corrosion threshold for a “mild” environment. To be classified as a mild environment, which is required for rooms that industrially house electronics, over 30 days the copper cannot accumulate more than 299 Angstroms, nor the silver accumulate more than 199 Angstroms, of total corrosion.

Screen_Shot_2018-01-12_at_2.52.40_PM.png

Supporting DIY monitoring

Sara Wylie and her research team at Northeastern University started using Purafil Corrosion Coupons alongside their DIY photopaper sampling canisters to gain insight into what hydrogen sulfide concentrations were causing discoloration of the photopaper. The laboratory analysis of the Purafil coupons provides defensible information about the corrosivity of an environment, and Wylie et al have been using them to develop a sort of calibration curve for photopaper discoloration.

We're hoping to utilize these coupons to generate calibration curves for visual discoloration of DIY copper sheet tests too. Since humidity is such an important factor is accelerating corrosion, pairing DIY copper sheet tests with humidity sensors and the corrosion coupons will be essential. At >$200 each, the corrosion coupons aren't cheap, but if a handful of pilot tests can be used to provide a range of relationships between visual cues and measured corrosion, then it could really launch the incredibly inexpensive DIY copper sheet hydrogen sulfide monitoring method, which is the goal!